Problem

A company that provided flight simulators suffered a noise problem from the operation of two large hydraulic pumps that were installed in a room that measured 6 by 6 meters. As a result, it affected three groups of recipients:

  • Pilots who used the flight simulators were disturbed while using the simulators.
  • Mechanics and maintenance personnel as the noise level exceeded the legal limit.
  • Office staff, who sat above the hydraulic pump room, were disturbed while working.

Cause

When measuring noise level in the hydraulic pumps room, it was found that:

  • The direct noise from the hydraulic pumps had an average noise level of 95 dBA and a noise frequency of 500 Hz
  • Reverberation noise occurred from the noise of hydraulic pumps reflecting on the floor, ceiling, and room walls and became a reverberation noise with high intensity
  • The hydraulic pumps room had strong walls and structures, but it was not initially designed as a soundproofing room

Improvement Protocol

After the site survey, NTi completed the following procedures:

  • Measured the noise level from the noise source and the perception points of each recipient group
  • Indicated the problem with FFT (Fast Fourier Transform) technique and conducted octave contour
  • Conducted noise simulation models of noise control with various materials and methods
  • Assessed the noise level reduction at each recipient point and cost of each approach to facilitate the customer’s decision making process
  • Installed sound-absorbing/soundproofing systems in the hydraulic pump room according to the approach chosen by the customer

Improvement result

  • The average noise level in the hydraulics pump room decreased from 95-98 dBA to 75-80 dBA
  • Engineers and maintenance technicians no longer had to shout at each other to communicate or wear ear protection equipment
  • Pilots could use flight simulators without being disturbed by noise
  • Office staff located above the hydraulic pumps room could work normally
  • Building occupants were not distracted from their work while the flight simulators were in use