Problem
The affected people were employees working in an office room in the production area who were disturbed by the operation of air heaters. The air heaters were pieces of equipment for the production system and converted raw materials in order to produce goods. Each heater was placed 6 meters away from the office room and had intermittent noise that occurred periodically when in operation. As a result of the disturbance, the employees could not concentrate in the office, had to use loud voices to communicate with each other, and had to shout while using the phone. It caused employees to develop health problems such as sore throat, tinnitus, discomfort, and increased stress levels. The customer wanted to reduce the noise source without any modifications taking place in the office area. Therefore, the NTi acoustical engineering department analyzed the sound data and found out that this noise problem could be controlled by installing "acoustic jackets" or removable acoustic jackets onto the air heaters.
Cause
Air heaters were located near the office room and created a loud noise that penetrated into the office room (single-source issue)
Improvement
When NTi was contacted to solve the noise problem in the area, we found that air heaters were used to dissipate raw materials moisture and it resulted in a noise level which is detailed in the table below.
| Noise level before improvement |
Measure at the noise source |
Measure inside the office |
| Air Heaters working (dBA) | 97.0 | 73.5 |
| Air Heaters not working (dBA) | 77.4 | 58.1 |
| Increased noise level (dBA) | 19.6 | 15.4 |
After completing the installation and measuring the noise level again, the noise level was as shown in the table below.
| Noise level of Air Heaters | Measure at the noise source | Measure inside the office |
| Without acoustic jackets (dBA) | 97.0 | 73.5 |
| With acoustic jackets (dBA) | 83.7 | 62.1 |
| Decreased noise level (dBA) | 13.3 | 11.4 |
Improvement result
After reducing the air heaters' noise by installing "acoustic jackets", the noise level at the noise source was reduced to 13.3 dBA, and the noise level inside the office room dropped to 11.4 dBA. Additionally, the noise level in the office room increased by only 4.0 dBA when air heaters were in operation. This improvement allowed employees in the office room to work with greater ease. They no longer had to shout to communicate or suffer loud noise in their workplace.