Problem
An ice block production factory received a noise complaint from local residents who lived behind the factory. The noise could be heard more clearly at nighttime when most residents needed to sleep and rest. The factory revealed that the noise came from reciprocating ammonia compressors that were in operation almost 24 hours a day. The reciprocating ammonia compressors were installed in the back end of the factory building, which was located just 6 meters away from the residential houses.
Cause
The main noise source was the operating noise of two reciprocating ammonia compressors (direct sound), which were placed approximately 8 meters apart in a room with dimensions of 12 meters by 20 meters. A secondary problem was the reverberation that occurred in the walls and floors of the building. After measuring the noise level while the reciprocating ammonia compressors were operating, it was found that the average noise level was 86-90 dBA. Data collection occurred during the rainy season and in a limited timeframe. Therefore, these aforementioned conditions made it impossible to measure the nighttime annoyance level of the local residents.
Improvement result
Improvement Protocol