Problem

A factory received complaints from local residents about noise disturbance, which negatively affected their lives both day and night. When inspecting the factory, the engineer responsible for the area revealed that the noise problem came from the wind noise in the air pollution control stacks. As part of the production process, the air pollution control stacks were about 12 meters above the ground and placed horizontally parallel to each other. The noise that occurred could be heard from several hundred meters away, especially at nighttime.

Cause

When inspecting the location of the air pollution control system installed in the factory building, it was found that the air pollution control system consisted of a dust filter bag and a centrifugal blower. The power source of the air pollution control system was a direct non-belt-driven induction motor with inverter speed control including an air duct connected to the air ventilation stack. One of the main causes of noise disturbance was the polluted air that was vented through stacks without using silencers and the noise level in the air pollution control system was 27.0 dBA.

Improvement Protocol

  • Surveyed the problem area to collect noise data and related machinery data
  • Performed a waveform analysis to identify the real noise problem
  • Created a mathematical noise simulation model to find a noise reduction method
  • Designed passive silencers that were a suitable size for the sound power
  • Manufactured sound reduction equipment and installed it at the end of both stacks
  • Collected noise data after the installation to make a report to compare the results between before and after the improvement

Improvement result

  • The noise level at the end of stacks was reduced from 27.0 dBA to 7.0 dBA
  • The noise level of stacks was within the legal limit of 10.0 dBA
  • Local residents no longer suffered from the noise problem and could live beside the factory as usual