Portfolio >> Coffee Extractor
Portfolio
ผลงาน

Problem

A coffee manufacturer factory wanted to reduce the noise exposure for employees who worked in a production area where there were noise sources from a variety of machinery and equipment. However, the loudest noise source which exceeded legal standards came from two adjacent coffee extractors. After measuring the noise level while the coffee extractors were working, it was found that the noise level was in the range of 88-92 dBA. The noise characteristics that occurred while the coffee extractors were operating were high-frequency and consistent noise.

Cause

Coffee extractors were installed in an open area, where steam and heat were generated while they operated. Workers in the area had been afraid that if the coffee extractors were covered with acoustic enclosures or soundproofing rooms there could be a heat build-up problem. Therefore, they believed that maintenance or inspection would be problematic. As a result, the coffee extractors were used without any noise control equipment.

Improvement Protocol

  • After noise identification, it was found that the noise coming from the coffee extractors was the main problem.
  • Identified noise characterization and discovered that the noise frequency range was 1,000-1,600 Hz
  • Calculated the soundproofing value (TL: Transmission Loss) of materials, which could withstand high temperatures
  • Designed open-sided soundproofing rooms for cooling, and created doors on all sides
  • Calculated the optimal height of the room that turned the working area into a shadow zone
  • Simulated the noise level in the working area then compared the differences of soundproofing rooms of coffee extractors and not.

Improvement results

  • The average noise level in the working area decreased from 88-92 dBA to 83-85 dBA
  • The person who was responsible for maintenance or working with coffee extractors could still work normally
  • No heat build-up or vapor condensation impeded coffee extractors operation